Trash > Electricity Trainer
Electricity Trainer
KL-100
|
Features
Ideal for electricity circuit experiments and design exercises.
- Integrated training system, with complete curriculum.
- Built-in power supplies and test facilities for easy and efficient experimentation.
- Large breadboard for circuit design and prototyping.
- 11 experiment modules form basis for nearly 60 fully documented experiments.
- Main units and experiment modules also available separately for economical construction of class sets.
The KL-100 Electricity Trainer is a comprehensive and self-contained system suitable for tuition and experimentation with a range of electricity circuits.
|
KL-100 Main Unit
The main unit incorporates all necessary equipment for use with the eleven plug-on training modules. Power supply, function generator, and analogue and digital meters are all built-in.
The DC power supply provides fixed ±5V and ±12V at 0.3A, a variable ±3V ~ ±18V at 1A, and a transformer provides a 9V~0V~9V AC output at up to 500mA.
The function generator offers sine, square, and triangle waveforms at frequencies from 10Hz ~ 100kHz in 4 ranges.
The main unit is also supplied with a removable 1680 tie point universal breadboard for general experimentation and prototyping.
KL-100 Experiment Modules
Eleven modules form the basis for the 59 experiments detailed in the comprehensive experiment manual. Each module contains the experiment circuit which is clearly illustrated by a cicuit diagram on its top panel. Switch faults are also incorporated into the modules for simulating fault situations.
|
|
KL-13001 Basic Electricity Experiment Module |
|
KL-13002 Magnetism Introduction Experiment Module |
|
KL-13003 Magnetic Field Experiment Module |
|
KL-13004 Ampere's Rule Experiment Module |
|
KL-13005 Fleming's Rule Experiment Module |
|
KL-13006 Induction Experiment Module |
|
KL-13007 Fundamental Electronic Circuits Experiment Module |
|
KL-13008 Basic Electronic Circuits (1) Experiment Module |
|
KL-13009 Basic Electronic Circuits (2) Experiment Module |
|
KL-13010 Special Electronic Components Experiment Module |
|
KL-13011 Oscillator Characteristics & Applications Experiment Module |
|
The full list of experiments performed using the above modules and detailed in the experiment manual are:
- Basic Electricity Experiments
- DC voltage measurement
- Using an ohmmeter
- Resister characteristics
- DC current measurement
- Ohm's law
- Power in DC ciruits
- Series-parallel circuits and Kirchhoff's law
- Superposition, Thevenin's and Norton's theorems
- Maximum power transfer theorem
- DC RC circuits and transient phenomena
- AC voltage measurement
- AC current measurement
- AC RC circuits
- AC RL circuits
- AC RLC circuits
- Power in AC circuits
- Transformer characteristics
- Series resonant circuits
- Parallel resonant circuits
- LC filters
- Magnetism Experiments
- Magnetic devices
- Magnetic fields
- Drawing magnetic curves
- Magnetic field strength
- Lenz's and Faraday's laws
- Ampere's rule
- Fleming's rule
- Self induction
- Mutual induction
- Magnetic flux detection
- Fundamental Electronic Circuits Experiments
- Diode characteristics
- Rectifier circuits
- Filter circuits
- Zener diode characteristics
- LED characteristics
- Transister characteristics
- Multimeter functions
- FET characteristics
- SCR characteristics
- UJT characteristics
- Basic Electronic Circuits Experiments
- Simple amplifier
- Complimentary amplifier
- Voltage regulator
- Push-pull amplifier
- Wheatstone bridge
- Dimmer circuit
- Multistage cascading amplifier
- Relay characteristics
- Touch controlled switch
- Control Applications Experiments
- CDS characteristics
- Light controlled circuit
- Thermister characteristics
- Temperature controlled circuit
- Sound controlled circuit
- Oscillator Characteristics & Applications Experiments
- Blocking oscillator
- Electronic birdcall circuit
- Astable multivibrator
- LED flasher circuit
- LC resonant circuit
Specifications
| KL-100 Main Unit |
| Fixed DC Power Supply |
Voltage range: +5V, -5V, +12V and -12V Maximum current output: 300mA Output overload protection |
| Variable DC Power Supply |
Voltage range: +3V ~ +18V, -3V ~ -18V Maximum current output: 1A Output overload protection |
| AC Power Supply |
Voltage range: 9V~0V~9V Maximum current output: 500mA Output overload protection |
| Function Generator |
Four frequency ranges: 10Hz to 100Hz 100Hz to 1KHz 1KHz to 10KHz 10KHz to 100KHz Waveforms: Sine, Square, Triangle Accuracy: ±5% of full scale value Output impedance: 50W Output voltage: ³18Vp-p (open-loop); ³9Vp-p (with 50W load) |
| 3½ Digit Digital Meter |
DC Voltage range: 2V, 200V DC Voltage accuracy: ±0.3% of reading + 1 digit DC current range: 200µA, 2000mA DC current accuracy: ±0.5% of reading + 1 digit |
| Analogue Meters |
AC current: 0 ~ 100mA ~ 1A AC Voltage: 0 ~ 15V DC current: 0 ~ 100mA ~ 1A DC Voltage: 0 ~ 20V |
| Speaker |
8W, 0.25W speaker with driver circuit |
| Variable Resistors |
1kW, 0.25W variable resistor with 3 terminals (A, B, C) 10kW, 0.25W variable resistor with 3 terminals (A, B, C) 100kW, 0.25W variable resistor with 3 terminals (A, B, C) 1MW, 0.25W variable resistor with 3 terminals (A, B, C) |
| Removable Solderless Breadboard |
1680 interconnected tie points, accepting all DIP devices, components with leads and solid wires of AWG #22-30 (0.3mm to 0.8mm) |
| Accessories |
Power lead, connecting leads, fuse, dust cover, and user manual
|
| Power Supply |
110/220V AC ±10% 50/60Hz |
| Physical Characteristics |
Dimensions: 400mm (width), 300mm (depth), 130mm (height) Weight: 5.8kg | |
|
|