~3 Function LCR Measurement |
|
~1% Basic Accuracy |
|
~High Resolution 0.1uH, 0.1pF and 1m |
|
~Dissipation Factor Measurement |
|
~Zero Adjustment |
|
~Optional Accessory TL-06 for SMD Type Compoment |
|
|
|
|
|
SPECIFICATIONS |
|
Capacitance |
|
|
Range |
200pF, 2nF, 20nF, 200nF, 2uF, 20uF, 200uF, 2mF, 20mF in 9 ranges |
|
Accuracy |
200pF~200uF +(1% rdg + 2 digits), 2mF~20mF +(2% rdg + 10 digits) |
|
Dissipation |
Range 0~1.999 |
|
Factor |
Accuracy |
2nF < Cx < 2uF + (1% + 10 + 2000 / Cx) |
|
|
|
2uF < Cx < 2mF + (1% + 20 + 2000 / Cx) |
|
|
|
200pF and 20mF no specified |
|
|
|
Indutance |
|
Range |
200uH, 2mH, 20mH, 200mH, 2H, 20H, 200H in 7 ranges |
|
Accuracy |
200H +(3% rdg + 2 digits), 200uH, 2H~20H +(2% rdg + 2 digits), 2mH~200mH +(1% rdg + 2 digits) |
|
Dissipation |
Range 0~1.999 |
|
Factor |
Accuracy |
Lx + 200mH + (1% + 10 + 2000 / Lx) |
|
|
|
200mH~200H + (2% + 20 + 2000 / Lx) |
|
|
|
Resistance |
|
|
Range |
2ohm, 20ohm ,200ohm , 2kohm , 20kohm , 200kohm ,2Mohm, 20Mohm in 8 ranges |
|
Accuracy |
2ohm +(1% + 5 digits) 20ohm~200kohm +(1% + 2 digits) 2Mohm~20Mohm +(2% + 2 digits) |
|
|
|
Others |
|
|
Low Battery Warning |
Show "LO BAT" when the 5% of battery life remained |
|
Current Consumption |
10mA |
|
Temperature |
Operation 0C ~ 40C, Storage -20C ~ 70C |
|
|
|
Display |
0.5' digital height, 3 1/2 digits LCD |
|
|
|
Power Source |
Single 9V 006P battery |
|
|
|
Accessories |
Test leads GTL-107, Spare fuse(0.125A) *1, Operation manual Option: TL-06 SMD Type measuring clip |
|
|
|
Dimensions & Weight |
88(W) x 40(H) x 177(D) mm, Approx. 400g |
|
|
|
|
|
|