Home > Products > TEST & MEASURING INSTRUMENTS > Network Analyzer
Network Analyzer
7631
Downloadable Data Sheet
|
Introduction |
|
|
|
7631 Vector Network Analyzer adopted the technique of Direct Digital Synthesis (DDS) signal generator and multi-receiver. With high accuracy and large dynamic range, 7631 can quickly complete the transmission, reflection, phase and group delay measurement. 7631 is the perfect tool to test linear or nonlinear equipment in RF system (Radio Station, CATV, receiver equipment or other wireless communication systems).
7631 is ideal for testing of narrowband filters, SAW devices, amplifiers, antennas, impedance converters, cable and so on. Also automatic conformity testing and rapid testing is favorite and useful for volume production.
Test result can be printed or transferred to PC. It can also be recalled by the user to have a contrast test at any time.
|
|
|
|
|
Model's Type |
|
Automatic Pass/Fail test |
|
|
|
Double Channels and Double Windows Display |
|

|
|
Input/Output |
|
|
|
|
Front Panel |
Type-N Input and Output port, USB1.1 port |
|
|
Rear Panel |
RS-232, parallel interface, standard VGA output and standard keyboard interface |
|
|
|
|
|
|
|
7631A |
Input Impedance: 50 Ohm. Mainly used for telecom and broadcast series testing |
|
7631B |
Input Impedance: 75 Ohm. Mainly used for CATV testing |
|
|
Main Specifications |
|
|
|
Source Characteristics |
|
|
|
|
|
|
Frequency Range |
300KHz¡«1.3GHz |
|
Frequency Resolution |
10Hz |
|
Frequency Stability |
<5¡Á10-6 |
|
Phase Noise |
<-67dBc/Hz(10KHz Offset) |
|
Output Level Range |
-55dBm¡«+5dBm |
|
Level Flatness Harmonic Rejection |
¡Ü¡À1.5dB (+5¡æ¡«+30¡æ) ¡Ý30dB (1M¡«1300M) ¡Ý25dB(300K¡«1M) |
|
Directivity |
>50dB (After vector calibration) |
|
|
|
|
|
Receiver Characteristics |
|
|
|
|
|
|
IF Bandwidth |
100Hz¡«15KHz |
|
Upper Limit Frequency |
1.3GHz |
|
Dynamic Range |
¡Ý100dB (RBW=1KHz at 2MHz¡«1300MHz) |
|
Maximum Input Level |
+10dBm |
|
Port VSWR |
¡Ü 1.2 |
|
|
|
|
|
Display Characteristics |
|
|
|
|
|
|
Logarithm Scale |
0.01dB/DIV¡«50dB/DIV |
|
Linearity Scale |
1uV/DIV¡«10 V/DIV |
|
Resolution |
0.01dB |
|
Sweep Time |
165ms/field¡«5s/field |
|
|
|
|
|
Measurement Characteristics |
|
|
|
|
|
|
Measurement Channel: |
2 channels (4 traces display) |
|
Measurement Mode |
A, B, R, A/R, B/R and A/B |
|
Measurement Format |
log/linear magnitude, phase, group delay, the real part and the imaginary part of a complex parameter, VSWR, Smith chart, Polar display. |
|
|
|
|
|
Other specifications |
|
|
|
|
|
|
Power Supply |
AC 90V¡«240V/50Hz,P ¡Ü 113 W |
|
Weight |
About 20 Kg |
|
Working Temperature |
0¡æ¡«40¡æ |
|
Store Temperature |
-10¡æ¡«5¡æ |
|
Hard Disk Space |
8M Byte |
|
Dimensions |
About 400mm¡Á220mm¡Á470mm |
|
|
|
|
|
|
|
|
|
|
Vector calibration before start |
|
The calibration can eliminate the error existing in system and enhance testing accuracy. 7631 have three vector receivers and provide self-calibration function including both amplitude and phase calibration. As a result, it can efficiently eliminate the error resulted from test port, test fixture port, cable and connecter. The calibration data is saved and applied in test procedure to obtain a wider dynamic range and higher accuracy. |
|
|
|
Normalization Calibration |
|
A general calibrating method to get better accuracy in transmission test, which can improve the level accuracy and flat of swept signal generator, receiver absolute accuracy, insertion loss arose by test fixture and so on. |
|
Application in CATV devices production |
|
|
|
7631B is a 75Ohm Vector Network Analyzer, which is specially designed for CATV devices production. It can test amplifiers, splitters£¬terminal box cable, SAW devices and so on. Especially for weak signals, transmission measurement can be hardly realized by a common network analyzer. |
|
|
|
Amplifier Measurement |
|
With high precision receiver and accurate signal level from signal source, 7631B can perform quality measurement, such as working frequency range, gain, flat, AGC feature, return loss and isolation, and gain compression of amplifier. Also, power sweep is available to catch 1db compression point of amplifier. 7631 provides various test and display modes to support high accuracy testing, especially for reflection strictly requested in bi-direction digital HFC network. |
|
|
|
|
Splitter Measurement |
|
7631 allows users to do transmission and reflection test of splitter at one display in virtue of double receivers, such as insertion loss, isolation, return loss and reflection coefficient, gain, attenuation, phase, group delay and so on |
|
Application in passive device test |
|
|
|
|
|
Filter testing |
|
7631 can not only test various types of filter transmission and reflection, but also with intelligent analysis module accurately display center frequency, NdB bandwidth, insert loss, Q value and group delay. The automatic Pass/Fail judgement function can significantly speed up the test. The special two windows mode helps users to test filter both in narrowband and wideband and to provide all filter parameters list. |
|
|
|
|
|
Antenna testing |
|
The main function parameters of antenna are directional diagram, gain, input impedance, standing wave ratio, polarization method, and return loss. With 7631 you can easily test medium wave antennas, short wave antennas and the antennas with the frequency under 1300MHz. |
|
|
|
|
|
|