Programmable Logic Controller Trainer (SIEMENS)
PLC-2240
Downloadable Data Sheet

(I) PLC CPU Unit
- I/O Capacity : 24 points
- Timers & Counters : 256 timers / counters
- Data Memory : Read / Write : 2560 words ; Read-only : 512 words
- Interrupt Processing : External interrupt = 4
- Interval Timer Interrupts : 1
- Memory Protection : HR and Read / Write DM area contents; and Counter values maintained during power interruptions.
- Self-Diagnostic Functions : CPU unit failure (watchdog timer), I/O bus error, and memory failure.
- Program Checks : No END instructions, programming error (continuously checked during operation).
- High-Speed Counter : One high-speed counter : 6 x 30Khz single-phase & 4 x 30Khz two-phase
- Pulse Output : Two points at 20Khz pulse rate
- Input Time Constants : Can be set to 1 ms, 2ms, 4ms, 8ms, 16ms, 32ms, 64ms or 128ms.
- Analog Controls : 2 controls.
- Build-In RS 232 adapter on PPI cable
- PPI cable with RS232 / RS485 converter
- PLC Training Manual
- Ladder Programming Software (Windows) c/w Manual
- Programming Console Since lot of limitation with console, it is advisable to use PC
- Accessories : Power Cord, Cable, Manual
(II) Trainer Base Consist Of :
- Indicator Lamps for all outputs (10 points)
- standard 4mm electrical sockets Terminal For Input and Output
- Switches for all inputs (14 nos)
Technical Specification
|
Physical Size |
|
|
Dimensions (WxHxD) |
330mmx113mmx330mm |
|
Weight |
Approx. 3 kg |
|
Power Loss (dissipation) |
Approx. 16.5W at full load (i.e. with additional loads connected. |
|
CPU Features |
|
|
On-board digital inputs |
14 inputs. (Additional connectors to external switches are provided. Built-in switches are toggle type.)
|
|
On-board digital outputs |
10 outputs. (Indicator lamps) |
|
High speed counters (32-bit value) |
|
|
|
Total |
6 High-speed counters |
|
|
Single Phase Counters |
6, each at 30kHz max. clock rate |
|
|
Two Phase Counters |
4, each at 30kHz max. clock rate |
|
Pulse outputs |
2 at 20 kHz pulse rate |
|
Analog adjustments |
2 with 8-bit resolution |
|
Timed interrupts |
2 with 1 ms resolution |
|
Edge interrupts |
4 edge up and/or 4 edge down |
|
Selectable input filter times |
7 ranges from 0.2 ms to 12.8 ms |
|
Pulse Catch |
14 pulse catch inputs |
|
Time of Day Clock (clock accuracy) |
2 minutes per month at 25°C
7 minutes per month at 0°C to 55°C |
|
Program size (stored permanently) |
4096 words |
|
Data block size (stored permanently) : |
2560 words |
|
|
Stored permanently |
|
2560 words |
|
|
Backed by super capacitor or battery |
|
2560 words |
|
Number of Expansion I/O modules |
7 modules |
|
Maximum digital I/O |
256 points |
|
Maximum analog I/O |
32 inputs and 32 outputs |
|
Internal memory bits |
256 bits |
|
|
Stored permanently on power down |
|
112 bits |
|
|
Backed by super capacitor or battery |
|
256 timers |
|
Timers total |
256 bits |
|
|
Backed by super capacitor or battery |
|
64 timers |
|
|
1 ms |
|
4 timers |
|
|
10 ms |
|
16 timers |
|
|
100 ms |
|
236 timers |
|
Counters total |
256 counters |
|
|
Backed by super capacitor or battery |
|
256 counters |
|
Boolean execution speed |
0.37 µs per instruction |
|
Move Word execution speed |
34 µs per instruction |
|
Timer/Counter execution speed |
50 µs to 64 ps per instruction |
|
Single precision math execution speed |
46 µs per instruction |
|
Real math execution speed |
100 µs to 400 µs per instruction |
|
Super capacitor data retention time |
190 hours, typical,
120 hours minimum at 40°C |